Starna

Spectrophotometer reference materials

61 references for Spectrophotometer reference materials.

ReferenceVariant
RM-HLHolmium oxide liquid cell, wavelength reference 240 to 650 nm
RM-HGHolmium oxide glass filter, wavelength reference 240 to 640 nm
RM-DLDidymium oxide liquid cell, wavelength reference 290 to 870 nm
RM-DGDidymium glass filter, wavelength reference 430 to 890 nm
RM-RECerium sulfate liquid cell, far UV wavelength reference 200 to 300 nm
RM-SLSamarium oxide liquid cell, wavelength reference 230 to 560 nm
RM-HDLHolmium/didymium liquid cell, wavelength reference 240 to 795 nm
RM-HNLHolmium/neodymium liquid cell, wavelength reference 220 to 865 nm
RM-HG/1NDHolmium/neutral density glass filter, wavelength and 1 A absorbance check
RM-DG/1NDDidymium/neutral density glass filter, wavelength and 1 A absorbance check
RM-2065Wide-range wavelength reference, 335 to 1945 nm
RM-DUV/195Deep UV reference, 190 to 220 nm
RM-0204060810Potassium dichromate linearity set, 20 to 100 mg/L with blank, 0.09 to 1.5 A
RM-020406081060Potassium dichromate linearity set, 20 to 100 mg/L and 600 mg/L with blank, for Ph. Eur.
RM-121416182224Potassium dichromate linearity set, 120 to 240 mg/L with blank, 1.5 to 3.5 A
RM-040812162024Potassium dichromate linearity set, 40 to 240 mg/L with blank, 0.19 to 3.5 A
RM-06A12A18A24ANicotinic acid linearity set, 6, 12, 18 and 24 mg/L with blank, 210 to 260 nm
RM-25G50G75G100GStarna Green linearity set, four concentrations with blank, 250 to 650 nm
RM-1Q3Q9QMetal-on-quartz filter set, 10, 30 and 92 %T with blank holder, NIST SRM 2031c equivalent
RM-9QMetal-on-quartz filter, 92 %T (0.04 A)
RM-5QMetal-on-quartz filter, 50 %T (0.3 A)
RM-3QMetal-on-quartz filter, 30 %T (0.5 A)
RM-2QMetal-on-quartz filter, 20 %T (0.7 A)
RM-1QMetal-on-quartz filter, 10 %T (1.0 A)
RM-Q3Metal-on-quartz filter, 3 %T (1.5 A)
RM-Q1Metal-on-quartz filter, 1 %T (2.0 A)
RM-DQ1Metal-on-quartz filter, 0.1 %T (3.0 A)
RM-AQ1Metal-on-quartz filter, 0.01 %T (4.0 A)
RM-4NDNeutral density glass filter set of 4, 440 to 635 nm
RM-6NDNeutral density glass filter set of 6, 440 to 635 nm
RM-9NDNeutral density glass filter set of 9, 440 to 635 nm
RM-1N2N3NNeutral density filter set, 10, 20 and 30 %T with blank holder, NIST SRM 930e equivalent
RM-N1N35NNeutral density filter set, 1, 3 and 50 %T with blank holder, NIST SRM 1930 equivalent
RM-D1D39NNeutral density filter set, 0.1, 0.3 and 92 %T with blank holder, NIST SRM 2930 equivalent
RM-SRM9NDNeutral density filter set of 9 with blank holder, NIST SRM equivalent
1N3N5DHGVisible spectrophotometer qualification set: neutral density filters 1.00, 0.50 and 0.25 A with holmium glass filter
RM-ACKCSISN/15Universal stray light reference set, Ph. Eur. and USP compliant
RM-SNSodium nitrite stray light cell, cut-off 391 nm
RM-ACAcetone stray light cell, cut-off 326 nm
RM-KIPotassium iodide stray light cell, cut-off 260 nm
RM-SISodium iodide stray light cell, cut-off 260 nm
RM-LCLithium carbonate stray light cell, cut-off 227 nm
RM-SCSodium chloride stray light cell, cut-off 201 nm
RM-KCPotassium chloride stray light cell, cut-off 201 nm
RM-SN/5Sodium nitrite stray light cells, 10 and 5 mm, filter ratio method
RM-AC/5Acetone stray light cells, 10 and 5 mm, filter ratio method
RM-KI/5Potassium iodide stray light cells, 10 and 5 mm, filter ratio method
RM-SI/5Sodium iodide stray light cells, 10 and 5 mm, filter ratio method
RM-KC/5Potassium chloride stray light cells, 10 and 5 mm, filter ratio method
RM-G275Stray light glass WG275, usable 210 to 270 nm
RM-G380Stray light glass GG380, usable 270 to 350 nm
RM-G475Stray light glass GG475, usable 350 to 440 nm
RM-TXToluene in hexane resolution cell with hexane blank
RM-TMToluene in methanol resolution cell with methanol blank, for derivative spectroscopy
RM-BZBenzene vapour resolution cell
RM-NIRNIR wavelength reference cell, 900 to 2600 nm
RM-NIR/TNIR transflectance wavelength reference cell, 900 to 2600 nm
RM-CHCL3Chloroform stray light cell for NIR
RM-1921/38Polystyrene mid-IR and FTIR reference, 38 µm
RM-1921/65Polystyrene mid-IR, FTIR and NIR reference, 65 µm
RM-1921/38/ATRPolystyrene mid-IR and FTIR reference for ATR, 38 µm