ReferenceVariant
82-P0050Pressure transducer 0-50 bar (connecting cable not included)
82-P0050/CPressure transducer 0-50 bar (connecting cable not included) with traceable calibration certificate
82-P0100Pressure transducer 0-100 bar (connecting cable not included)
82-P0100/CPressure transducer 0-100 bar (connecting cable not included) with traceable calibration certificate
82-P0200Pressure transducer 0-200 bar (connecting cable not included)
82-P0200/CPressure transducer 0-200 bar (connecting cable not included) with traceable calibration certificate
82-P0349/ELTConnecting cable for pressure transducer, Suitablefor Smart-Line, Sercomp, MCC, Advantest control consoles and Compact-Line compression machines
82-P0350Pressure transducer 0-350 bar (connecting cable not included)
82-P0350/CPressure transducer 0-350 bar (connecting cable not included) with traceable calibration certificate
82-P0500Pressure transducer 0-500 bar (connecting cable not included)
82-P0500/CPressure transducer 0-500 bar (connecting cable not included) with traceable calibration certificate
82-P0700Pressure transducer 0-700 bar (connecting cable not included)
82-P0700/CPressure transducer 0-700 bar (connecting cable not included) with traceable calibration certificate
82-Q50/PT700 bar pressure transducer with steel C-shape protection, hydraulic cylinder T-connector and connecting cable for Smart-Line, Sercomp
62-C0171Air entrainment meter for mortar 1 L capacity
62-C0171/AAir entrainment meter for mortar 0,75 L capacity
62-C0171/1Filling ring
63-L0037/11Spare tamper for EN flow tables
64-L0056Marsh funnel
64-L0057Mud balance
62-L0074/UUStainless steel container with lid for for five prisms 25x25x280 mm to UNI 11504 and/or for one prism 75x75x285 mm to UNI 11604, Supporting rack for specimen/s to be purchased separately
62-L0073/5Specimen supporting rack for five mortar prisms 25x25x285 mm
50-C92W02WIZARD AUTO COMPACT-Line automatic compression machine, 600 kN capacity for testing cement, mortar, resin, hydraulically bound mixtures and other materials, 230 V, 50/60 Hz, single-phase
50-C92W04WIZARD AUTO COMPACT-Line automatic compression machine, 600 kN capacity for testing cement, mortar, resin, hydraulically bound mixtures and other materials, 110 V, 60 Hz, single-phase
50-C92W22WIZARD AUTO COMPACT-Line automatic compression machine double chamber 600/15 kN capacity for testing cement, mortar, resin, 230 V, 50/60 Hz, single-phase
50-C92W12WIZARD AUTO COMPACT-Line automatic compression machine, 500 kN capacity for testing cement, mortar, resin, hydraulically bound mixtures and other materials, 230 V, 50/60 Hz, single-phase
50-C92W14WIZARD AUTO COMPACT-Line automatic compression machine, 500 kN capacity for testing cement, mortar, resin, hydraulically bound mixtures and other materials, 110 V, 60 Hz, single-phase
50-C92W24WIZARD AUTO COMPACT-Line automatic compression machine double chamber 600/15 kN capacity for testing cement, mortar, resin, hydraulically bound mixtures and other materials, 110 V, 60 Hz, single-phase
65-L0050/HRDSupply of the machine cement machines/frames L28xxx with traceable certificate of hardness of testing platens surfaces (one upper and one bottom platen certification included)
50-C10W/2FSecond frame facility for WIZARD AUTO series, frame selection via manual lever
50-Q60W/PRUpgrading the WIZARD AUTO series to incorporate a serial graphic printer in the rear panel
50-C99/PRigid safety guard for the 15 kN chamber of the multipurpose machines
65-L008050 mm three gang cube mould
65-L0015/AAutomatic flexure/tension machine, 5 kN capacity 230 V, 50 Hz, single-phase
65-L0015/AYAutomatic flexure/tension machine, 5 kN capacity 220 V, 60 Hz, single-phase
65-L0015/AZAutomatic flexure/tension machine, 5 kN capacity 110 V, 60 Hz, single-phase
65-L0015/1Flexure attachment NF-DIN-UNI-EN
65-L0015/4Tensile attachment for briquette
65-L0015/5Flexure testing attachment ASTM
65-L0016Briquette mould
62-L0048Metal measure 400 ml capacity
62-D1635Chattaway spatula
63-L0040/11Hardwood tamper 12x25x150 mm
63-L2700/E24Glass base plate
63-L0075Gillmore apparatus
64-L0053/AMould for grout spread test to EN 445
22-T0040/1Glass plastic limit plate 300 x 300 mm
64-L0054/AFlow trough for the determination of work ability of grouts and mortars to EN 13395-2
65-L0019/B1Marking template for centreing cement prism 40x40x160 mm for flexural test
65-L0010/CSix gang mould 12 x 40 x 160 mm according to EN 14891
62-L0037Brass ring mould
62-L0073Mortar bar container - ASTM C 227
62-L0073/1Supporting rack for prism 75x75x285 mm to UNI 11604
62-L0009/A3 gang mould with plugs for the measurement of dimension variations to UNI 8520-22
62-L0009/A1Spare plugs for mould 62-L0009/A, pack of 20 pcs
62-L0034/11Reference rod 294 mm for mould 62-L0009/A
62-L0033/UUTwo gang prism mould 75x75x285 mm to UNI 11604 forthe detection of potential alkali-reactivity of aggregates for concrete
62-L0033/UOne gang prism mould 75x75x285 mm to UNI 11604 forthe detection of potential alkali-reactivity of aggregates for concrete
62-L0034/1Reference INVAR rod 295 mm long to ASTM C490
62-L0033/U1Spare contact points to UNI 11604 (30 pcs)
64-L0035/DApparatus for testing reactivity of quicklime to EN459-2, supplied with digital thermometer, serialcable for PC connection and software for data download, 110-240 V, 50/60 Hz, single-phase
64-L0035/EApparatus for testing reactivity of quicklime to EN459-2, supplied with digital thermometer, 110-240 V, 50/60 Hz, single-phase
64-L0035/C1Spare Dewar vessel for 64-L0035/x apparatus supplied without stopper
64-L0035/C2Stirring paddle for 64-L0035/x
64-L0035/D1Spare thermometer for 64-L0035/D -Max, temperature: 900°C -Resolution: 0.1°C -Accuracy: +/- 0.5°C
64-L0035/E1Spare thermometer for 64-L0035/E. -Max.temperature: 220° C -Resolution: 0.1° C -Accuracy: ± 0.3° C
64-L0064Kit for the analysis of sand content
62-L0041/ESemi-automatic Blaine air permeability apparatus to EN 196-6, ASTM C204, BS 4550
62-L0025Le Chatelier mould
62-L0025/BLe Chatelier soundness kit
62-L0025/CLe Chatelier moulds, set of 6
62-L0025/FLe Chatelier water bath, 220-240 V, 50/60 Hz, single-phase
62-L0025/FZLe Chatelier water bath, 110 V, 60 Hz, single-phase
64-L0025/GSteam bath to EN 459-2, 230 V, 50/60 Hz, single-phase
62-L0003Le chatelier flask
65-L0013/DCURACEM, cement curing cabinet EN 196-1, Requires input of water at 8 °C, See refrigerator 86-D2031, Air compressor not included, 230 V, 50/60 Hz, single-phase
65-L0013/DZCURACEM, cement curing cabinet to EN 196-1, Requires input of water at 8 °C, See refrigerator 86-D2031, Air compressor not included, 110 V, 60 Hz, single-phase
65-D2031Water cooler, max power 800W, 230 V, 50/60 Hz, single-phase
65-D2031/ZWater cooler, max power 800W, 110 V, 60 Hz, single-phase
65-L0013/D1Heavy duty air compressor, Air tank 200 L cap230 V, 50 Hz, single-phase
65-D1326Plastic pan 220x220x70 mm for water curing of three 40x40x160 mm cement specimens
65-L0010/AThree gang mould 40 x 40 x 160 mm according to EN 196-1
65-L0010/B40x40x160 mm three gang for mortar prism, min, hardeness HV400, with traceable certifi- cate for the EN 196 properties and rust inibitor treatment
65-L0010/5Plugs for thermal expansion measurement, 2 type, Bshape according EN 1770, pack of 12 pieces
65-L0010/PThree gang plastic mould 40 x 40 x 160 mm with lid
62-L0033/B2Contact points for 62-L0033/B, pack of 10
65-L0050/AVibrating machine for 70.7 mm cube mould, conf, toBS 4550
65-L0050/AYVibrating machine for 70.7 mm cube moulds, 220 V, 60 Hz, single-phase
65-L0050/AZVibrating machine for 70.7 mm cube moulds, 110 V, 60 Hz, single-phase
65-L005170.7 mm cube mould without base for the use with 65-L0050 vibrating machine
62-L0061/BCement water retention apparatus including: aspirator pump, vacuum gauge with regulator, stopcock, flask, rubber gasket, glass funnel, perforeted brass dish and stand
62-L0061/CCement water retention apparatus including: vacuumpump with ultimate vacuum 0.1 mbar, digital vacuumregulator with vacuum gauge 1 mbar resolution, three way stopcock
62-L0058Wet sieving apparatus
64-L0098Apparatus for determination of workable life of mortars to EN 1015-9 method A
54-C2010/AComputerized concrete calorimeter for the determination of the heat of hydration to EN 12390-15
54-C2010/A1Spare mould for adiabatic calorimeter
54-C2010/8Set of 3 spare copper tubes
54-C2010/5Spare convective paste, 50 g
65-L0512Automatic programmable mortar mixer, 5 liters capacity, with mixing bowl, EN beater and open type sand hopper
65-L0514Automatic programmable mortar mixer, 5 liters capacity, with mixing bowl, EN beater and open type sand hopper
65-L0512/ASStainless steel beater for automatic mixer series 65-L051x conforming to ASTM C305
65-L0512/1Additional open-type hopper suitable for automatic mixer series 65-L051x
65-L0512/2Spare stainless steel bowl for automatic mixer series 65-L051x, 5 liters capacity
65-L0005/5Hard rubber scraper
65-L0512/ENStainless steel beater for mixer series 65-L050x and 65-L051x, conforming to EN 196-1 if combined with mixer series 65-L051x
65-L0007/1Reference sand to EN 196, 32 bags, tot, 43,20 kg
65-L0007/3Reference sand similar to ASTM C 778, Graded sand, TYPE SILICA SAND, 1 bag of 25 kg, This sand is not from French origin and not from USA
65-L0502Digital mortar mixer, 5 liters capacity with mixing bowl and beater
65-L0504Digital mortar mixer, 5 liters capacity with mixing bowl and beater
65-L0502/2Spare stainless steel bowl for digital mortar mixer series 65-L050x, 5 liters capacity
65-L0502/1Open-type hopper suitable for digital mortar mixerseries 65-L050x
62-L0060/AApparatus for measurement of bulk density of cement
62-L0004Apparatus for the determination of Carbon Dioxide content in cement, conforming to EN 196-2 230 V, 50/60 Hz, single-phase
86-D2001Portable vacuum pump, free air displacement 75 L/min, ultimate vacuum 0.1 mbar, 230 V, 50/60 Hz, single-phase
86-D2004/1Vacuum regulator valve
86-D2001/ZPortable vacuum pump, free air displacement 75 L/min, ultimate vacuum 0.1 mbar, 110 V, 60 Hz, single-phase
82-D1259/BDial gauge 50 mm x 0.01 mm
82-D1260Magnetic holder for dial gauges
82-D1258Non return device for dial gauges
63-L0028Vicat test set EN method
63-L0028/AVicat test set ASTM method
63-L0028/1Vicat apparatus
63-L0028/21Initial/final needle 1 mm diameter set of 6
63-L0028/31Initial needle 1,13 mm diameter set of 6
63-L0028/41Stainless steel final needle with special foot (single piece)
63-L0028/5Consistency plunger 10 mm diameter
63-L0028/6Supporting glass plate
63-L0028/7Glass thermometer -10 + 50c
63-L0028/8Additional weight 700 g
63-L0027/E22Plastic mould to EN
63-L0027/E23Plastic mould to ASTM/AASHTO
63-L0028/10Conical needle diameter 8x50 mm to EN 13279 for gypsum testing, with probe, total weight 100 g
62-L0071/AEHeat of hydration calorimeter with high resolution digital thermometer, 230 V, 50/60 Hz, single-phase
62-L0071/AEZHeat of hydration calorimeter with high resolution digital thermometer, 110 V, 60 Hz, single-phase
62-L0071/3Filler funnel
62-L0071/6Spare Dewar flask for calorimeter model 62-L0071/Aand L0071/AD
62-L0072/VSpecial set of glassware for water content determination including silica combustion tube and water absorption components, BS 4550, UNI 7208
86-D0805Paraffin wax 1000 g
62-L0041/CBlaine apparatus, ASTM C204 and EN 196-6
62-L0041/A1Spare U-tube glass manometer for 62-L0041/A and 62-L0041/C
62-L0041/32Filter paper for apparatus 62-L0041/A, Dia, 12,6mmPack of 100 pcs
62-L0041/2Manometer liquid 250 ml bottle
62-L0041/6Reference cement according to EN 196.6 and ASTM C204 - pack of 5 g
62-L0009Shrinkage mould for 40 x 40 x 160 mm mortar prisms
62-L0009/GShrinkage mould for 40 x 40 x 160 mm mortar prisms to EN 12617-4
62-L0009/1Spare shrinkage plugs to UNI 6687 (pack of 12)
62-L0009/1FSpare shrinkage plugs to EN 12617-4 (pack of 12)
62-L0010/H2Contact points for 10x040x160 mm specimens to EN 12808-4, pack of 12
62-L0034/7Rod 160 mm long
62-L0010/H3Plastic insert 15x40x160 mm for shrinkage mould 62-L009/F conforming to EN 12808-04, pack of 6
65-L0006/AMAUTOMIX, automatic programmable mixer with sand dispenser and additional feeder for general purposes, Bowl capacity 5 L, 220-230 V, 50/60 Hz, single-phase
65-L0006/AMZAUTOMIX, automatic programmable mixer with sand dispenser and additional feeder for general purposes, Bowl capacity 5 L, 110 V, 60 Hz, single-phase
65-L0006/6Steel wisk for AUTOMIX mixer
65-L0006/2Stainless steel bowl for AUTOMIX mixer, 5 lt capacity conforming to EN 196
65-L0006/4Stainless steel beater for AUTOMIX mixer conforming to EN 196
65-L0006/5Steel whisk for AUTOMIX with threaded hole, model without link connection ring, high mixing capacity
62-L0032/AHigh pressure cement autoclave, 230 V, 50/60 Hz, single-phase
62-L0032/AZHigh pressure cement autoclave, 110 V, 60 Hz, single-phase
62-L0033/BTwo gang prism mould 25x25x285 mm to ASTM C490 for expansion test of cement
64-L0062Kleine apparatus to EN459-2 for carbon dioxide determination in lime
10-B0145/EHot plate maximum temperature 280 °C and magnetic stirrer, 100 to 1500 rpm, capacity 3 liters, 200-240 V, 50/60 Hz, single-phase
64-L0055/AFlow cone apparatus with 10 mm diameter nozzle, metal stand and sieve 1,5 mm ap, to EN 445
64-L0055/2Nozzle, 8 mm inside diameter
64-L0055/3Nozzle, 9 mm inside diameter
64-L0055/5Nozzle, 11 mm inside diameter
64-L0055/6Nozzle, 13 mm inside diameter
64-L0055/1Stainless steel cone without nozzle
64-L0055/4Nozzle, 10 mm inside diameter
64-L0055/7Stainless steel sieve, 150 mm diameter, 1.5 mm opening
63-L0040/GMotorised flow table with digital counter, with flow mould and tamper, conforming to ASTM C230, user interface: large size graphic display and membrane keyboard, 230 V, 50 Hz, single-phase
63-L0040/AFlow table with mould, hand operated, with flow mould and tamper, conforming to ASTM C230
63-L0040/GYMotorised flow table with digital counter, with flow mould and tamper, conforming to ASTM C230, user interface: large size graphic display and membrane keyboard, 220 V, 60 Hz, single-phase
63-L0040/GZMotorised flow table with digital counter, with flow mould and tamper, conforming to ASTM C230, user interface: large size graphic display and membrane keyboard, 110 V, 60 Hz, single-phase
64-L0038/AHand operated flow table for building lime, with flow mould, hopper and tamper, Compliant with EN 459-2, 13279-2, 1015-3
64-L0038/GMotorized flow table to EN 459-2, 13279-2, 1015-3 with digital counter, with flow mould, hopper and tamper, user interface: large size graphic display and membrane keyboard, 230 V, 50 Hz, single-phase
64-L0038/GYMotorized flow table to EN 459-2, 13279-2, 1015-3 with digital counter, with flow mould, hopper and tamper, user interface: large size graphic display and membrane keyboard, 220 V, 60 Hz, single-phase
64-L0038/GZMotorized flow table to EN 459-2, 13279-2, 1015-3 with digital counter, with flow mould, hopper and tamper, user interface: large size graphic display and membrane keyboard, 110 V, 60 Hz, single-phase
63-L0037/1Flow calliper
63-L0037/10Brass flow mould for EN flow tables
63-L0037/12Spare filling hopper for EN flow mould
63-L0038/10Spare inox flow mould for EN flow tables
63-L0040/1Brass flow caliper conforming to ASTM-BS standars
63-L0040/10ASTM and BS mould for flow table
63-L2701/EVICAMATIC-3, automatic electronic apparatus for setting time test on cement/mortar/gypsum, 110-240 V, 50/60 Hz, single-phase
63-L2701/FVICAMATIC-3, automatic electronic apparatus for setting time test on cement/mortar/gypsum, with ASTM C191 accessories: initial setting time needle 1 mm diameter and mould, 110-240 V, 50/60 Hz, single-phase
63-L2701VICAMATIC-3, automatic electronic apparatus for setting time test on cement/mortar/gypsum, supplied without accessories (mould, needle) and mould cenetering ring, 110-240 V, 50/60 Hz, single-phase
63-L2700/E10Accessory for in-water testing
63-L2700/E11LAN HUB for PC connection of up to 7 VICAMATIC units or up to 6 units in case of multi-hub network, LAN cable from hub to PC is included, each VICAMATIC unit is with LAN cable
63-L2700/E14Needle for final setting test to EN
63-L2700/E15Cylindrical probe for consistency test
63-L2700/E16Additional weight 700 g (EN 480-2)
63-L2700/E18Conical penetration probe 8 mm diameter x 50 mm with 100 g calibrated weight for gypsum testing to EN 13279
63-L2700/E201,13 mm diameter needle to EN
63-L2700/E9Water thermostatic unit for up to 2 VICAMATIC units, 230 V, 50/60 Hz, single-phase
63-L2700/E9ZWater thermostatic unit for up to 2 VICAMATIC units, 110 V, 60 Hz, single-phase
63-L2700/F15Cylindrical probe and additional weight for consistency test to ASTM C807
63-L2700/PRUpgrading of a VICAMATIC unit for incorporating a graphic printer into the head
63-L2700/1Centreing ring for EN mould
63-L2700/2Centreing ring for ASTM mould
63-L2700/E211 mm diameter needle to ASTM/AASHTO
63-L2700/E25Spare base plate for in-water testing kit
63-L2700/F212 mm diameter needle to ASTM C807
63-L2700/F23Brass mould diameter 76 mm x 40 mm to ASTM C807
63-SW/VSVICASOFT-PREMIUM PC software to connect up to 32 VICAMATIC-2 units including remote control of eachunit, data acquisition - processing - filing, printout of test reports
82-D1261/50CDigital dial gauge 50x0,01 mm with output for PC connection (special cable required)
82-D1262/BHigh resolution digital indicator 25.4 x 0.001 mm
64-L0036Plunger penetration apparatus to EN 413-2, 459-2, 1015-4, with cup and tamper
65-L18Z10300 kN capacity hydraulic frame for compression tests on cement, mortar, resin and other materials, conforming to EN 196-1, 1015-11, ASTM C109, C349 using the suitable accessories
65-L28Z10300/15 kN capacity double chamber hydraulic frame for compression and flexure tests on cement, mortar, resin and other materials, conforming to EN 196-1,1015-11
65-L38Z10300 kN capacity hydraulic frame for compression tests on cement, mortar, resin and other materials, conforming to EN 196-1, 1015-11, ASTM C109, C349 using the suitable accessories
65-L58Z1015 kN capacity hydraulic frame for compression tests on low-strength materials or flexure tests on prisms made of cement, mortar, resin, and other materials
65-L3800/PTransparent rigid safety guard for testing frame series 65-L38xxx
65-L0050/PSafety guard opening switch for L type frames and machines
65-L1800/PTransparent rigid safety guard for testing frame series 65-L18xxx and 65-L58Z10
65-L2800/PTransparent rigid safety guard for testing frame series 65-L28xxx
64-L0063/AFilter press for mud with filter paper sheets, pipe nipple, 25 ml glass cylinder, and CO2 pressing assembly, CO2 cartridges not included
64-L0063/A1CO2 cartridges for L0063/A (pack of 10)
64-L0063/A2Filter paper for L0063/A (pack of 100)
65-L18F12AUTOMAX PRO automatic compression machine, 300 kN capacity for compression tests on cement, mortar, resin and other materials, conforming to EN 196-1, 1015-11, ASTM C109, 230 V, 50/60 Hz, single-phase
65-L18F14AUTOMAX PRO automatic compression machine, 300 kN capacity for compression tests on cement, mortar, resin and other materials, conforming to EN 196-1, 1015-11, ASTM C109, 110 V, 60 Hz, single-phase
65-L38F12AUTOMAX PRO automatic compression machine, 300 kN capacity for compression tests on cement, mortar, resin and other materials, conforming to EN 196-1, 1015-11, ASTM C109, 230 V, 50/60 Hz, single-phase
65-L38F14AUTOMAX PRO automatic compression machine, 300 kN capacity for compression tests on cement, mortar, resin and other materials, conforming to EN 196-1, 1015-11, ASTM C109, 110 V, 60 Hz, single-phase
65-L27F12AUTOMAX PRO automatic double chamber compression machine, 15/300 kN capacity for compression and flexure tests on cement/mortar prisms 40x40x160 mm.Conforming to EN 196-1, 230 V, 50/60 Hz, single-phase
65-L27F14AUTOMAX PRO automatic double chamber compression machine, 15/300 kN capacity for compression and flexure tests on cement/mortar prisms 40x40x160 mm.Conforming to EN 196-1, 110 V, 60 Hz, single-phase
65-L28F12AUTOMAX PRO automatic double chamber compression machine, 15/300 kN capacity for compression and flexure tests on cement, mortar, resin and other materials, 230 V, 50/60 Hz, single-phase
65-L28F14AUTOMAX PRO automatic double chamber compression machine, 15/300 kN capacity for compression and flexure tests on cement, mortar, resin and other materials, 110 V, 60 Hz, single-phase
50-Q60P/PRUpgrading the AUTOMAX PRO and PILOT PRO series to incorporate a serial graphic printer in the rear panel allowing load/time plot
65-L2701/PTransparent rigid safety guard for testing frame series 65-L27xxx, suitable only for models fitted with load cells
82-P0340/100High precision displacement transducer, LDT type, 100 mm travel,output 2mv/v
82-P0340/50High precision displacement transducer, LDT type, 50 mm travel,output 2mv/v
82-P0340/10High precision displacement transducer, LDT type, 10 mm travel,output 2mv/v
82-P0340/5High precision displacement transducer, LDT type, 5 mm travel,output 2mv/v
65-L0014/DFour compartments bench-type curing cabinet, 230 V, 50-60HZ/single-phase
65-L0014/DZFour compartments bench-type curing cabinet, 110 V, 60HZ/single-phase
65-L0014/C1Additional plastic coated shelf for bench type curing cabinet series L0014
65-L0014/RECUpgrade of the Cabinet for soring of humidity and temperature values (one every 10 minutes) and download of data via Webserver (max storage of 12 months then data will be overwritten).The upgrade shall ba factory installed
65-L0014/HWFiltration kit, Suggested in case mains water hardness is higher than 20 f