9010-0075
ED 400, drying and heating chamber with natural convection, with RS 422, 400 L interior, +5 °C above ambient temperature to 300 °C, 400 V 50/60 Hz three-phase, designation ED400-400V-I
- Manufacturer
- BINDER
- Reference
- 9010-0075
- Item type
- Laboratory incubator and drying oven
Specifications
- Designation
- ED400-400V-I
- Option model
- With RS 422
- Temperature range
- +5 °C above ambient temperature to 300 °C
- Temperature uniformity at 150°C
- 3.0 ± K
- Temperature fluctuation at 150°C
- 0.5 ± K
- Heating up time to 150°C
- 71 min
- Recovery time after door was opened for 30 s at 150°C
- 31 min
- Air change rate at 150°C
- 10 x/h
- Rated voltage
- 400 V
- Power frequency
- 50/60 Hz
- Nominal power
- 3,4 kW
- Unit fuse
- 16,0 A
- Phase (nominal voltage)
- 3~/N/PE
- Interior volume
- 400 L
- Net weight of the unit (empty)
- 125 kg
- Load per rack
- 35 kg
- Permitted load
- 90 kg
- Wall clearance back
- 160 mm
- Wall clearance sidewise
- 100 mm
- Width net
- 1,235 mm
- Height net
- 1,025 mm
- Depth net
- 765 mm
- Interior width
- 1,000 mm
- Interior height
- 800 mm
- Interior depth
- 520 mm
- Unit doors
- 2
- Energy consumption at 150°C
- 672 Wh/h
- Number of shelves (std./max.)
- 2/10
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- 9010-0002B 28, standard incubator with mechanical adjustment, 28 L interior, 30 to 70 °C, 230 V 50/60 Hz, designation B028-230V
- 9010-0067B 28, standard incubator with mechanical adjustment, 28 L interior, 30 to 70 °C, 120 V 60 Hz, designation B028-120V
- 9010-0323BD 56, standard incubator with natural convection, 57 L interior, +5 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BD056-230V
- 9010-0324BD 56, standard incubator with natural convection, 57 L interior, +5 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BD056UL-120V
- 9010-0325BD 115, standard incubator with natural convection, 112 L interior, +5 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BD115-230V
- 9010-0326BD 115, standard incubator with natural convection, 112 L interior, +5 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BD115UL-120V
- 9010-0329BD 260, standard incubator with natural convection, 253 L interior, +5 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BD260-230V
- 9010-0330BD 260, standard incubator with natural convection, 253 L interior, +5 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BD260UL-120V
- 9010-0331BD 720, standard incubator with natural convection, 737 L interior, +5 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BD720-230V
- 9010-0332BD 720, standard incubator with natural convection, 737 L interior, +5 °C above ambient temperature to 100 °C, 240 V 50/60 Hz, UL version, designation BD720UL-240V
- 9010-0313BF 56, standard incubator with forced convection, 59 L interior, +7 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BF056-230V
- 9010-0314BF 56, standard incubator with forced convection, 59 L interior, +7 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BF056UL-120V