9010-0320
BF 260, standard incubator with forced convection, 257 L interior, +7 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BF260UL-120V
- Manufacturer
- BINDER
- Reference
- 9010-0320
- Item type
- Laboratory incubator and drying oven
Specifications
- Designation
- BF260UL-120V
- Option model
- Standard
- Temperature range
- +7 °C above ambient temperature to 100 °C
- Temperature uniformity at 37°C
- 0.2 ± K
- Temperature uniformity at 100°C
- 1.2 ± K
- Temperature fluctuation at 37°C
- 0.1 ± K
- Temperature fluctuation at 100°C
- 0.3 ± K
- Heating up time to 100°C
- 30 min
- Heating up time to 37°C
- 7 min
- Recovery time after door was opened for 30 s at 37°C
- 3 min
- Rated voltage
- 120 V
- Power frequency
- 60 Hz
- Nominal power
- 1 kW
- Unit fuse
- 12,5 A
- Phase (nominal voltage)
- 1~
- Interior volume
- 257 L
- Net weight of the unit (empty)
- 85 kg
- Load per rack
- 40 kg
- Permitted load
- 270 kg
- Wall clearance back
- 160 mm
- Wall clearance sidewise
- 100 mm
- Width net
- 810 mm
- Height net
- 845 mm
- Depth net
- 760 mm
- Interior width
- 650 mm
- Interior height
- 780 mm
- Interior depth
- 510 mm
- Inner doors
- 1
- Unit doors
- 1
- Sound-pressure level
- 43 dB(A)
- Energy consumption at 100°C
- 275 Wh/h
- Energy consumption at 37°C
- 65 Wh/h
- Number of shelves (std./max.)
- 2/8
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- 9010-0002B 28, standard incubator with mechanical adjustment, 28 L interior, 30 to 70 °C, 230 V 50/60 Hz, designation B028-230V
- 9010-0067B 28, standard incubator with mechanical adjustment, 28 L interior, 30 to 70 °C, 120 V 60 Hz, designation B028-120V
- 9010-0323BD 56, standard incubator with natural convection, 57 L interior, +5 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BD056-230V
- 9010-0324BD 56, standard incubator with natural convection, 57 L interior, +5 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BD056UL-120V
- 9010-0325BD 115, standard incubator with natural convection, 112 L interior, +5 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BD115-230V
- 9010-0326BD 115, standard incubator with natural convection, 112 L interior, +5 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BD115UL-120V
- 9010-0329BD 260, standard incubator with natural convection, 253 L interior, +5 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BD260-230V
- 9010-0330BD 260, standard incubator with natural convection, 253 L interior, +5 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BD260UL-120V
- 9010-0331BD 720, standard incubator with natural convection, 737 L interior, +5 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BD720-230V
- 9010-0332BD 720, standard incubator with natural convection, 737 L interior, +5 °C above ambient temperature to 100 °C, 240 V 50/60 Hz, UL version, designation BD720UL-240V
- 9010-0313BF 56, standard incubator with forced convection, 59 L interior, +7 °C above ambient temperature to 100 °C, 230 V 50/60 Hz, designation BF056-230V
- 9010-0314BF 56, standard incubator with forced convection, 59 L interior, +7 °C above ambient temperature to 100 °C, 120 V 60 Hz, UL version, designation BF056UL-120V