BCM-810

Spectrophotometric colourimeter

Manufacturer
BIOBASE
Reference
BCM-810
Product line
Colourimeters

Specifications

Product
Spectrophotometric colourimeter
Illumination/Observation System
d/8(diffused illumination, 8-degree viewing angle) Conforms to CIE No.15, GB/T 3978
Integrating Sphere Size
φ58 mm
Light Source
Combined LED sources
Sensor
Silicon photodiode array
Wavelength Range
400 to 700 nm
Wavelength Pitch
10 nm
Reflectance Range
0 to 200%
Measuring Aperture
φ8 mm
Colour Space
CIE LAB, XYZ, Yxy, LCh, CIE, LUV
Colour Difference Formula
ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00
Other Chromaticity Data
WI(ASTM E313, CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), metamerism index(Mt), colour strength, colour stain, colour fastness, opacity
Other Chromaticity Data
WI(ASTM E313, CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), metamerism index(Mt), colour strength, colour stain, colour fastness, opacity
Observer
2°/10°
Illuminant
D65, D50, A, C, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30)
Display Data
Spectral value/Graph, Colourimetric value, Colour difference value/Graph, Pass/Fail result, Colour offset, Colour simulation
Display Data
Spectral value/Graph, Colourimetric value, Colour difference value/Graph, Pass/Fail result, Colour offset, Colour simulation
Measurement Time
1.5s
Repeatability
Spectral reflectance: Standard deviation within 0.1% Colourimetric value: Standard deviation within ΔE*ab 0.04(Measurement conditions: White calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.)
Repeatability
Spectral reflectance: Standard deviation within 0.1% Colourimetric value: Standard deviation within ΔE*ab 0.04(Measurement conditions: White calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.)
Repeatability
Spectral reflectance: Standard deviation within 0.1% Colourimetric value: Standard deviation within ΔE*ab 0.04(Measurement conditions: White calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.)
Inter Instrument Agreement
Within ΔE*ab 0.2(Average for 12 BCRA Series II colour tiles)
Battery
Li-ion battery, 2800 times within 8 hours
Lamp Life
5 years, more than 1.6 million measurements
Display
3.5 inch TFT LCD, Capacitive touch screen
Interface
USB/RS-232
Data Memory
1000 standards, 15000 samples
Ambient Temp.
0 to 40 °C(32 to 104°F)
Storage Temp.
-20 to 50 °C(-4 to 122°F)
Standard Accessory
Power adapter, Li-ion battery, operating instruction, PC software(Download from office website), data line, white and black calibration cavity, protective cover, wrist strap
Optional Accessory
Universal test components, micro printer, powder test box

Add this reference to my quote

Set the quantity and delivery on the interactive catalogue.

Request a quoteAll references for this item