EA2-2F
Class II A2 Biological Safety Cabinet, interior 600 x 500 x 540 mm, external size(w*d*h) 700 x 700 x 2000 mm, tested opening Safety height 200 mm
- Manufacturer
- BIOBASE
- Reference
- EA2-2F
- Product line
- Class II A2 Biological Safety Cabinet
- Item type
- Biological safety cabinet, Class II
Specifications
- External Size(W*D*H)
- 700 x 700 x 2000 mm
- Internal Size(W*D*H)
- 600 x 500 x 540 mm
- Tested Opening
- Safety height 200 mm
- Max Opening
- 360 mm
- Inflow Velocity
- 0.53±0.025m/s
- Downflow Velocity
- 0.33±0.025m/s
- ULPA Filter
- Two, 99.9995% efficiency at 0.12 μm, filter life indicator
- Front Window
- Manual and electric. Tempered glass≥5 mm. Anti UV.
- Noise
- ≤65 dB
- UV Lamp
- 15 W*1 UV timer, UV life indicator, emission of 235.7 nanometers for most efficient decontamination
- LED Lamp
- 8 W*2
- Illumination
- ≥1000 Lux
- Consumption
- ≤500 W
- Socket
- Two, total consumption: 500 W
- Display
- LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.
- Control System
- 70% air recirculation, 30% air exhaust
- Visual and Audio Alarm
- Filter replacement, window over height, abnormal air flow velocity, High filter pressure, abnormal power failure
- Material
- Work Zone: 304 stainless steel Main Body: Cold-rolled steel with anti-bacteria powder coating
- Work Surface Height
- 750 mm with base stand
- Power Supply
- AC220 V, 50/60 Hz; 110 V, 60 Hz
- Standard Accessory
- Cabinet*1, Base stand*1, LED lamp*2, UV lamp*2, Drain ball valve*1, Waterproof Socket*2, EC fan, Foot switch, Remote control
- Optional Accessory
- Water and gas tap, Electric height adjustable base stand, Armrest
- Package Size(W*D*H)
- Carton: 820 x 880 x 1470 mm
- Gross Weight
- 172 kg
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- EA2-3FClass II A2 Biological Safety Cabinet, interior 940 x 600 x 660 mm, external size(w*d*h) 1100 x 800 x 2200 mm, tested opening Safety height 200 mm(8")
- EA2-4FClass II A2 Biological Safety Cabinet, interior 1150 x 600 x 660 mm, external size(w*d*h) 1300 x 800 x 2200 mm, tested opening Safety height 200 mm(8")
- EA2-5FClass II A2 Biological Safety Cabinet, interior 1350 x 600 x 660 mm, external size(w*d*h) 1500 x 800 x 2200 mm, tested opening Safety height 200 mm(8")
- EA2-6FClass II A2 Biological Safety Cabinet, interior 1625 x 600 x 660 mm, external size(w*d*h) 1800 x 800 x 2200 mm, tested opening Safety height 200 mm(8")
- EA2-7FClass II A2 Biological Safety Cabinet, interior 1800 x 600 x 660 mm, external size(w*d*h) 1950 x 800 x 2250 mm, tested opening Safety height 200 mm(8")