sq16plus
Squirrel SQ16plus low-power multi-channel data logger
- Manufacturer
- Grant Instruments
- Reference
- sq16plus
- Product line
- Squirrel and OQ610 data loggers
- Item type
- Temperature data loggers
Specifications
- Specification
- Details
- Universal input
- Yes, including 2, 3 and 4 wire resistance
- Voltage ranges (differential and single ended)
- -0.3 to 0.3V, -1.5 to 2.5V, -6 to 10V, -40 to 60V
- Common mode
- 60V
- Current ranges (differential, requires external 10Ω shunt)
- 4 to 20mA, -30 to +30mA
- Thermocouple ranges (differential and single)
- K-type: -200 to 1372°C R-type: -50 to 1768°C B-type: 250 to 1820°C T-type: -200 to 400°C S-type: -50 to 1768°C C-type: 0 to 2320°C N-type: -200 to 1300°C J-type: -200 to 1200°C D-type: 0 to 2320°C
- Resistance ranges (2,3 & 4 wire)
- 0–2000Ω and 0–300000Ω (2-wire); 0–4000Ω (3-wire); 0–4000Ω (4-wire)
- Thermistor ranges
- U, UU, Y & S type – 50 to +150°C & customer-specific thermistors
- Pt100/1000, 2-wire
- -200 to 850°C
- Internal reference temperature
- -55 to 150°C
- Pulse count ranges
- 0 to 100Hz (2 input); 0 to 64kHz (2 input)
- Digital state/event ranges
- 0 to 34,360,000,000 count; 8 state inputs or 1 × 8-bit binary
- Digital/alarm outputs
- 4 open drain FETs, 40V, 0.1A
- A/D resolution
- 32 bit
- Accuracy
- Refer to operating manual
- Clock resolution/accuracy
- 1s / 10ppm
- Sampling rates
- Up to 100 readings per second on 2 channels
- Data statistics
- Yes, from within new SquirrelView Plus PC software
- Calculated channels
- Yes, up to 16
- Memory internal
- 16GB, approximately 800 million readings
- Multi-function button
- LED status indication and start/stop
- Internal battery
- 6 × AA cells
- Battery life
- Up to 6 months (all channels logging every 15 minutes)
- External power
- Yes, 8 to 38V DC or via USB
- Sensor power output
- 8–38V at 150mA when connected to external power supply
- Networking
- Via USB or OpenThread
- Modem support
- Via USB hub
- Actions & triggers (PC setup)
- Four alarm outputs; fully configurable actions and triggers
- Front panel setup
- Yes, SquirrelView compatible. Via smartphone app. All essential functionality available via app (e.g., channel configuration, start/stop logging). Advanced functions (e.g., calculated channels and descriptions) available via PC with SquirrelView.
- Stored setups
- 6
- Operating temperature
- -20 to 65°C
- Dimensions (W × D × H) / weight
- 257 × 206 × 57.3 mm, 1.5 kg
- Working environment
- –30 to 65°C, RH up to 95% (non-condensing)
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- OQ610-SOQ610 process temperature logger
- OMK 610 KIT1OQ610 logger kit with enhanced thermal barrier (to 250 °C for up to 100 minutes), USB cable and carry case
- OMK610 HSOQ610 logger with enhanced thermal barrier (to 250 °C for up to 100 minutes), probes ordered separately
- SQ16Squirrel SQ16 low-power multi-channel data logger
- sqhubSquirrel sqhub logging hub
- OMK610-NPOQ610 logger with thermal barrier (to 250 °C for up to 50 minutes), probes ordered separately