Model 14C

Ludlum Model 14C, general purpose survey meter

Manufacturer
Ludlum Measurements
Reference
Model 14C

Specifications

Product
Ludlum Model 14C, general purpose survey meter
Ludlum part number
48-1611
Application
Alpha, Beta, and Gamma surveying
Internal Detector
Energy compensated GM (used with ×1000 scale only) Range: 0 to 20 mSv/hr (0 to 2000 mR/hr) Sensitivity: 200 cpm per mR/hr
Compatible External Detectors
Any GM or Scintillation type operating on 900 VDC (see Compatible Detectors tab)
Detector Channels
External Detector: ×0.1 through ×100 range settings Internal GM Detector: ×1000 setting
Energy Response
Within 15% of true value between 60 keV to 3 MeV (internal detector only)
Linearity
Reading within 10% of true value with detector connected
Meter Dial
0 - 2 mR/hr, 0 - 5 kcpm, BAT TEST ( Meter Faces tab lists other available meter faces)
Meter
6.4 cm (2.5 in.) arc, 1 mA analog type
Controls
Rotary Selector Switch: Switches between: Off; Ranges: ×0.1, ×1, ×10, ×100, ×1000 Response Switch: Toggles between FAST (4 s) or SLOW (22 s) from 10% to 90% of final reading Reset Push Button: Zeroes meter Battery Push B
High Voltage
900 Vdc
Threshold
-40 mV ± 10 mV
Temperature Range
-20 to 50 °C (-4 to 122 °F)
Relative Humidity
95%
Power
2 each "D" cell batteries (housed in an externally accessible sealed compartment)
Battery Life
Typically greater than 2000 hours (battery condition can be checked on meter)
Construction
Cast and drawn aluminum with beige powder coat
Connector
Series "C" (others available)
Size (H x W x L)
16.5 × 8.9 × 21.6 cm (6.5 × 3.5 × 8.5 in.)
Weight
1.6 kg (3.5 lb), including batteries
Meter Face
Image (click to view larger)

Add this reference to my quote

Set the quantity and delivery on the interactive catalogue.

Request a quoteAll references for this item