5181207T7------B

Sartorius Sartofluor LG Mini Cartridge 0.2 µm Size 7, adapter 12 (1/2" screw adapter), filter size size 7 (0.05 m² / 0.5 ft²), filtration area 0.05 m², housing material Polypropylene (PP), Silicone (SI), delivery condition Non sterile - Autoclavable Steamable

Manufacturer
Sartorius
Reference
5181207T7------B

Specifications

Product type
Process filtration: sterilising-grade cartridges, capsules and integrity testers
Adapter
12 (1/2" screw adapter)
Application
Air/Gas Filtration
Application Area
Bioreactors (Inlet | Outlet) Storage tank venting Filling equipment venting Freeze dryer autoclave venting
Industry
Pharma / Biotech
Modality
Active Pharmaceutical Ingredients (Antibiotics solvents) Solvents
Scale
Production | Small Scale
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC 19146 per ASTM methodology
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Biocompatibility (USP Class VI)
USP <88>
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Extractables
The total amount of extractables is well below the limits established by the current USP unter "Sterile Water for Injection".
Filter Size
Size 7 (0.05 m² / 0.5 ft²)
Filtration Area
0.05 m²
Outer Diameter
56 mm
Capsule/Cartridge Format
Cartridges
Maximum Allowable Back Pressure
Cartridges GA | Mini Cartridges | Junior at 3 bar | 43.5 psi at 20 °C Cartridges LG | Maxicaps | Midicaps | Capsules at 2 bar | 29 psi at 20 °C
Maximum Diffusion
2 mL/min at 0.7 bar
Minimum Required Bubble Point
1.0 bar | 14.5 psi
Filter Material
Polytetrafluorethylene (PTFE)
Housing Material
Polypropylene (PP)
Material o-ring | seal
Silicone (SI)
Membrane Material
Polytetrafluorethylene (PTFE)
Support Fleece
Polypropylene (PP)
Maximum Differential Pressure
20 °C: 5 bar, 80 °C: 2 bar
Gamma Stable
No
Non-Fiber Releasing
This filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
Pore Size
0.2 µm
Filter Type
Membrane Filters
Type
Air filter
Delivery Condition
Non sterile - Autoclavable | Steamable
Sterilization Method
Autoclavable & In-Line Steam Sterilizable
Sterilizing Grade
Yes
Sterilization Procedures
Cartridges (GA & LG) | Mini Cartridges | Junior: Autoclaving at 134 °C, 2 bar | 29 psi, 30 min, sterilization cycles: min. 25 or In-Line Steam Sterilization at 134 °C, 20 min. at max differential pressure of 0.5 bar | 7.25 psi, sterilization cycles: max. 150, min. 25 (Mini Cartridges) Maxicaps | Midicaps | Capsules: Autoclaving at 134 °C, 2 bar | 29 psi, 30 min, sterilization cycles: min. 25 (Maxicaps | Midicaps), min. 5 (Capsules)
Product family