5441307I4G-OO--B

Sartorius Sartopore 2 XLI Gamma Capsule 0.2 µm Size 4 pack of 5, connector inlet 1/4" Multiple Stepped Hose Barb, connector outlet 1/4" Multiple Stepped Hose Barb, filter size size 4 (0.021 m² / 0.22 ft²), housing material Polypropylene (PP), Silicone (SI), delivery condition Non sterile - Gamma irradiatable

Manufacturer
Sartorius
Reference
5441307I4G-OO--B

Specifications

Product type
Process filtration: sterilising-grade cartridges, capsules and integrity testers
Application
High capacity platform for conventional sterile filtration
Industry
Pharma / Biotech
Modality
Media Filtration Buffer & Auxiliaries Filtration
Scale
Product Development | Scale Up Filters
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC 19146 per ASTM methodology
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Extractables
The total amount of extractables is well below the limits established by the current USP unter "Sterile Water for Injection".
Connector Inlet
1/4" Multiple Stepped Hose Barb
Connector Outlet
1/4" Multiple Stepped Hose Barb
Connector(s)
Inlet: ¼" Hose Barb | Outlet: ¼" Hose Barb
Filter Size
Size 4 (0.021 m² / 0.22 ft²)
Outer Diameter
63 mm (46 mm without Connection / Valves)
Capsule/Cartridge Format
Capsules
Maximum Allowable Back Pressure
2 bar (29 psi) at 20°C 1.5 bar (21.8 psi) at 50°C
Maximum Diffusion
1.1 mL/min at 2.5 bar | 36 psi at 20 °C
Minimum Required Bubble Point
3.2 bar | 46 psi
Vent Valve
Standard
Housing Material
Polypropylene (PP)
Material o-ring | seal
Silicone (SI)
Membrane Material
Polyethersulfone (PES)
Support Fleece
Polyester (PET)
Maximum Differential Pressure
20 °C: 4 bar, 50 °C: 2 bar
Maximum Operating Pressure
4 bar (58 psi)
Non-Fiber Releasing
This filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
Pore Size Final-filter
0.2 µm
Pore Size Pre-filter
0.35 µm
Delivery Condition
Non sterile - Gamma irradiatable
Sterilization Method
Gamma Irradiatable
Sterilization Procedures
Gamma Irradiation: with 50 kGy, 1 Cycle
Product family
Sartopore 2 XLI