SALD-7500nano

Nano particle size analyser, 405 nm laser, 7 nm to 800 µm with the sampler

Manufacturer
Shimadzu
Reference
SALD-7500nano

Specifications

Note1
Solvent resistance toward materials used in the passageways of SALD-MS75. Solvent resistance values are representative, and are not certified.
Note2
Only applicable for liquid pump. Not applicable for liquid supply pump.
Note3
Ultrasonic cleaning instruments are needed for the measurement of reference sample.
Measurement principle
Laser Diffraction Method
Measurement range
7 nm (0.007 μm) to 800 μm (when using sampler) 7 nm (0.007 μm) to 400 μm (when using batch cell) 30 nm (0.03 μm) to 280 μm (when using high-concentration sample unit)
Light source
Semiconductor laser (Wavelength 405 nm)
Light detector
Detector elements for violet semiconductor laser Total 84 elements (78 forward, 1 side, 5 back)
System compliance
Class 1 Laser Product, CE
Required power supply
AC 100 V±10%, 1 A, 50/60 Hz
Dimensions & weight
Approx. 680 × D280 × H430 mm, Approx.32 kg
Operation environment
Temperature : 10 to 30°C, Humidity : 20 to 80% (no condensation)
Dispersing bath
Capacity : 100 / 200 / 300 mL
Sonicator
Frequency : about32 kHz, output : about 40 W
Liquid pump
Radial pump, maximum flow rate 2000 cm 3 /min
Liquid pump material
Stainless (SUS 304, SUS 316), Tetrafluoroethylene (PTFE), Perfluoroelastmor (FEP)
Liquid supply pump
Diaphragm pump, maximum flow rate : 750cm 3 /min
Liquid supply pump material
Polypropylene
Flow cell
Quartz glass
Operating environment
Temperature: 10 to 30°C, Humidity: 20 to 80% (no condensation)
Cell material
Quartz glass
Required liquid volume
Approx. 5 cm 3
Stirrer mechanism
Up-and-down movement of blade
Measurement of particle size distribution
Allows measurements using measurement assistant unction (interactive process based on SOP) and manual mode
Automatic calculation of refractive index
Automatic calculation by Light Intensity Distribution Reproduction (LDR) method based on specified substance name or range
Real-Time display
Particle size distribution / Light intensity distribution simultaneous display
Recalculation of particle size distribution
Max. 200 data batch calculation or individual data calculation
Display of particle size distribution data
Max. 200 data overlay graph or individual data graph
Display of light intensity distribution
Max. 200 data overlay graph or individual data graph
Diagnostics/Adjustments
Self-diagnostic functions
Statistical data processing
Max. 200 data (Max. 200 data overlay graph)
Time series analysis
Max. 200 data
3-Dimensional graph
Max. 200 data
Data transfer via clipboard
Image Output, Image Output
Data sorting
Sort by file name, sample ID, sample number, or refractive index.
Particle size distribution (μm) number of divisions
Fixed 51 / 101 divisions / Optional (can be set by user) 51 divisions * 10 tables
Particle mass distribution (%) number of divisions
Fixed 51 divisions, Optical (can be set by user) 51 divisions * 10 tables
Dimension of particle amount
Count, length, area or volume
Expression of cumulative distribution
Undersize, oversize
Expression of data frequency
q, q / Δ×, q / Δlog×
Smoothing level
10 Level
Distribution function fitting
Rosin-Rammler distribution, logarithmic Gaussian distribution
Data shifting
±10 levels
Report functions
Batch output possible by selecting single data, overlay data, statistical data, time-series data, or 3D data
Scattering angle evaluation
Max. 200 data overlay graph or individual data graph
Data conversion function
Emulation of particle distribution data by other instruments or measuring principles
Mixing simulation function
Max. 6 points
Data connection function
2 data connections
Continuous measurements function
Measurement interval: 1 s min., Save up to 200 data points
Detection elements
84 elements
Options
Batch cell, multifunction sampler, high-concentration measurement system

Add this reference to my quote

Set the quantity and delivery on the interactive catalogue.

Request a quoteAll references for this item