TOC-4200
Online TOC analyser, 680 °C combustion catalytic oxidation with NDIR, 0 to 5 up to 0 to 1,000 mgC/L full scale, up to six streams
- Manufacturer
- Shimadzu
- Reference
- TOC-4200
- Product line
- TOC analyzers
- Item type
- TOC analyser
Specifications
- Measurement items
- TC, NPOC Optional: IC, POC, TOC (= TC-IC, = NPOC + POC), TN
- Measurement principle
- 680℃ combustion catalytic oxidation - NDIR detection method
- Measurement range
- From 0 - 5 to 0 - 1,000 mgC/L f.s. (0 to 20,000 mgC/L f.s. with dilution function)
- Repeatability
- Within ±2 % f.s. *1
- Span stability
- Within ±2 % f.s. /day (temperature variation within 5℃) *1
- Zero stability
- Within ±2 % f.s. /day (temperature variation within 5℃) *1
- Measurement cycle
- 4 minutes min. (NPOC, residual IC 2 % max.) *2
- Sample injection method
- Syringe pump/sliding injection port
- IC removal method
- Acidify/sparge within syringe
- Sample dilution function
- Dilution within syringe; dilution factor 2 to 50 Dilution accuracy: Within ±2 % (x2 to x20); within ±5 % (x21 to x50)
- Stream switching function
- Streams 1 to 6 can be switched (with the relevant option)
- Display, operation
- Colour LCD with touch screen
- Conversion function
- Conversion with a linear expression using required indices (Conversion expression must be determined in advance.)
- Load calculation function
- Using the analog input board (option) permits load calculations. (Non-isolated analog inputs; load resistance: 100 ohms)
- Data storage function
- Store 20,000 past on-line measured values (equivalent to one year's data at 30-minute measuring cycle). Offers trend graph displays.
- Data storage device
- Store measured values or measurement conditions to USB memory *3 . (USB 1.1 or 2.0 USB memory; FAT16 or FAT32; no encryption)
- Recorder
- Recording width 100 mm, 6-dot recorder (optional)
- Printer
- Thermal printer, 40 characters per line; 110 mm chart width (optional)
- Analog output
- Selectable between 4 – 20 mA DC or 0 – 16 mA DC (isolated outputs) With attached option: Up to 12 outputs (load resistance: 500Ω max.)
- Contact output signal
- Alarm signals Major failure, instrument alarm, power cut, CPU alarm, concentration alarm (upper limit/lower limit/upper upper limit/lower lower limit), measurement halted Event signals Maintenance, measurement ready, on-line operation, measuring sample, calibrating, regenerating catalyst, measuring control sample …
- Contact input
- Start calibration, stop measurement, start on-line measurement, reset alarm, measurement start flow line 1 to 6, halt measurement (output contact capacity: 1.4 V DC min., 10 mA min.)
- Communication function
- Compatible with RS-485, RS-232C (option), and Modbus Use the optional Web monitoring unit set to browse measured values and alarms on a Web browser over a LAN.
- Carrier gas
- Pressurized air, high-purity air, oxygen *4 ; supply pressure: 250 to 300 kPa Optional: High-purity nitrogen *4
- Power supply
- AC 100 to 240 V ±10%, 10 A, 50/60 Hz
- Ambient temperature
- Within 1 to 40℃
- Construction
- Indoor wall mounting (optional stand available)
- Dimensions
- W550 x D383 x H1240 mm (excluding protrusions) (W22 x D15 x H49 inches)
- Weight
- Approx. 70 kg (154 lbs.)
- Measurement items (*Optional)
- NPOC, TC, TOC (TC-IC)* TOC (NPOC+POC)*
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- TOC-L CSHLaboratory TOC analyser, 680 °C combustion catalytic oxidation with NDIR, TC 4 µg/L to 30,000 mg/L, standalone with colour touch screen
- TOC-L CPHLaboratory TOC analyser, 680 °C combustion catalytic oxidation with NDIR, TC 4 µg/L to 30,000 mg/L, PC-controlled
- TOC-L CSNLaboratory TOC analyser, 680 °C combustion catalytic oxidation with NDIR, TC 50 µg/L to 30,000 mg/L, standalone with colour touch screen
- TOC-L CPNLaboratory TOC analyser, 680 °C combustion catalytic oxidation with NDIR, TC 50 µg/L to 30,000 mg/L, PC-controlled
- TOC-V WPWet chemical oxidation TOC analyser with high-sensitivity NDIR
- ASI-LAutosampler for the TOC-L series
- OCT-LEight-port sampler for the TOC-L series, no special vials needed
- SSM-5000ASolid sample combustion unit, samples up to 1 g with up to 30 mg carbon
- TNM-LTotal nitrogen unit, 720 °C catalytic thermal decomposition with chemiluminescence detection