840-340200
Evolution Pro UV-Vis Spectrophotometer, 190 to 1100 nm, double beam, xenon flash lamp, 100/240 V, 50/60 Hz
- Manufacturer
- Thermo Fisher Scientific
- Reference
- 840-340200
- Product line
- UV-Vis Spectrophotometers
- Item type
- UV-Vis spectrophotometer (cuvette)
Specifications
- Fisher Scientific catalogue number
- 17319263
- Baseline flatness
- ±0.001 A (200 to 800 nm), 2.0 nm SBW, smoothed
- Detector type
- Dual Matched Silicon Photodiodes
- Light source
- Xenon Flash
- Product line
- Evolution Pro
- Spectral bandwidth
- 0.5, 1.0, 1.5, 2.0, 4.0 nm Selectable
- Type
- UV-Vis Spectrophotometer
- Wavelength range
- 190 to 1100 nm
- Drift
- <0.0005 A&fraslhr., 500 nm, 2.0 nm SBW, 2 hour warmup
- Electrical requirements
- 100/240 V, 50/60 Hz
- For use with (application)
- Academic, Chemicals, Food & Beverage, Chemicals Environmental, Industrial QA/QC, Material Science, Pharmaceuticals
- Includes
- Evolution Pro UV-Vis Spectrophotometer
- Lamp life
- >5 years or longer if not using live signal
- Noise
- 0A: 1A: 2A: 500 nm, 2.0 nm SBW, RMS
- Optical design
- Modified Ebert Double beam with sample and reference cuvette/accessory positions
- Pharmacopoeia compliance testing
- Wavelength Accuracy: ±0.3 nm 190–900 nm Wavelength Repeatability: SD 10 meas. Absorbance Accuracy: Absorbance Repeatability: ±0.0025A @ 1A Stray Light:
- Photometric accuracy
- 1 A: ±0.004 A,2 A: ±0.004 A, 3 A: ±0.006 A, Measured at 440 nm using neutral density filters traceable to NIST
- Photometric display
- ±6 A
- Photometric range
- >4 A
- Photometric repeatability
- 1 A: ±0.0025 A
- Scan ordinate modes
- Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, Log(1/R), Log(Abs), ABS × Factor, Intensity, 1st–4th Derivative
- Scan speed
- Variable, up to 6000 nm/min.
- Stray light
- KCl, 198 nm: ≤0.4% T NaI, 220 nm: ≤0.032% T NaNO2, 340 nm: <0.01% T
- Warranty
- 3-year Source Replacement Warranty
- Wavelength accuracy
- ±0.20 nm (546.07 nm Hg emission line), ±0.30 nm, 190 to 900 nm
- Wavelength data interval
- 10, 5, 2, 1, 0.5, 0.2, 0.1, 0.05 nm
- Wavelength repeatability
- Standard deviation of 10 measurements <0.05 nm
- Green features
- ACT Ecolabel (Gold)
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- 840-285300GENESYS 30 Visible Spectrophotometer Performance Verification Kit
- 840-277300GENESYS 30 Visible Spectrophotometer, EU Power Cable
- 840-277400GENESYS 30 Visible Spectrophotometer, UK Power Cable
- 840-340100Evolution Pro UV-Vis Spectrophotometer with mercury lamp, 190 to 1100 nm, double beam, 100/240 V, 50/60 Hz
- 912A1112Evolution Pro UV-Vis Spectrophotometers, Evolution Pro UV-Vis Spectrometer, INSIGHT Pro with Security Software, Validator for Insight Pro A4 Paper Version, Qualification Filter Kit for UV-Vis
- 840-372800Evolution Pro UV-Vis Spectrophotometers, Evolution Pro w/Mercury Lamp UV-Vis Spectrometer, INSIGHT Pro with Security Software, Validator for Insight Pro A4 Paper Version
- 912A1113Evolution Pro UV-Vis Spectrophotometers, Evolution Pro UV-Vis Spectrometer, INSIGHT Pro with Security Software, Validator for Insight Pro A4 Paper Version, USP and EP UV Standards Set
- 840-372900Evolution Pro UV-Vis Spectrophotometers, Evolution Pro w/ Mercury Lamp UV-Vis Spectrometer, INSIGHT Pro with Security Software, Validator for Insight Pro A4 Paper Version
- 840-300400GENESYS 150 UV-Vis Spectrophotometer, 190 to 1100 nm, dual beam, 100/240 V, 50/60 Hz, UK power cord