PSTAR2125

Orion Pro Star EC212 Conductivity Bench Meter with Stand, Meter with stand, 4-cell epoxy/graphite-body K=0.475 conductivity/ATC electrode, 1413 μS/cm conductivity standard pouches

Manufacturer
Thermo Fisher Scientific
Reference
PSTAR2125

Specifications

Fisher Scientific catalogue number
30245812
Includes
Meter with stand (PSTAR2120), 4-cell epoxy/graphite-body K=0.475 conductivity/ATC electrode (013005MD), 1413 μS/cm conductivity standard pouches
Accuracy (conductivity)
±0.5% reading
Outputs
USB flash drive, computer or printer (STARA-106)
For use with (application)
Wide variety of conductivity samples in the 1 μS/cm to 20 mS/cm range. Compliant with USP 645, EP 2.2.38, JP 2.51, EPA 120.1, ASTM D1125, ISO 7888, Standard Methods 2510B, USGS Ch. 6.3
Measurement modes
Conductivity with Temperature, TDS with Temperature, Salinity with Temperature, Resistivity with Temperature
Cell constant
0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1
Calibration
Conductivity, TDS, Salinity, Temperature
Calibration points (conductivity)
1 to 5 points
Calibration points
1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature)
Range (conductivity)
0.010 μS/cm to 3000 mS/cm
Resolution (conductivity)
0.001 μS/cm minimum, auto-ranging, up to 4 digits
Temperature compensation
Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off
Temperature (metric) reference
5, 10, 15, 20, 25 or 30°C
Range (salinity)
0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl
Resolution (salinity)
0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging
Accuracy (salinity)
±0.5% reading
Salinity measurement modes
Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl
Range (TDS)
0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00)
Resolution (TDS)
0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits
Accuracy (TDS)
±0.5% reading
TDS factor range
Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl
Temperature range
-30°C to +130°C
Resolution (temperature)
0.1°C, 0.1°F
Accuracy (temperature)
±0.3°C, ±0.5 °F
Range (resistivity)
1.0 Ω to 100.0 MΩ
Temperature selection
Automatic with ATC temperature sensor, ambient or manual
Temperature probe calibration
1 or 2 point temperature offset calibration
Display type
7-in. High-resolution Colour Graphic LCD
Backlight option
Yes
Memory
Non-volatile
Data points
10,000 with Date and Time Stamp
Log function type
Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode
Alarm output
Calibration reminder alarm, high and low limit alarm per parameter
Inputs
8-pin MiniDIN for conductivity with ATC
Certifications/Compliance
CE, TUV 3-1, FCC Class A
IP rating
IP54
AC adapter
Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets
Dimensions (L x W x H)
218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in.
Weight
1 kg
Warranty
2 year meter warranty
Model
EC212
Resolution (resistivity)
0.1 Ω minimum, auto-ranging
Methods
10
Keypad
Capacitive touchscreen user interface
Languages
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish
Channels
1
Type
Conductivity Bench Meter Standard Kit
Accuracy (resistivity)
±0.5% reading

Add this reference to my quote