VSTAR94

Orion Versa Star Pro pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter

Manufacturer
Thermo Fisher Scientific
Reference
VSTAR94

Specifications

Fisher Scientific catalogue number
15686775
AC adapter
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)
Outputs
USB (2), RS232
Accuracy (barometer)
±6 mmHg
Accuracy (conductivity)
0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Accuracy (ISE)
±0.2 mV or ±0.05% of reading whichever is greater
Accuracy (mV)
±0.2 mV or ±0.05% of reading whichever is greater
Accuracy (pH)
±0.002
Accuracy (polarographic DO)
±0.2 mg/L or ±2% of reading, whichever is greater
Accuracy (RDO)
±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L
Accuracy (resistivity)
0.5% of reading ±1 digit
Accuracy (salinity)
0.5% of reading ±1 digit
Accuracy (TDS)
0.5% of reading ±1 digit
Advanced ISE functions
Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit
Alarm output
Set point alarm, high/low limit alarm, calibration due alarm
Backlight option
Yes
Barometric pressure correction
400 to 850mmHg, automatic using built-in barometer or manual entry
Calibration
PH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
Calibration modes
Water-saturated air, air-saturated water, manual (Winkler titration), zero point
Calibration points
1 point relative mV (RmV) mode, 1 point ORP mode
Calibration points (conductivity)
Up to 6
Calibration points (ISE)
1 to 6
Calibration points (pH)
1 to 6
Cell constant
0.001 to 199.9cm-1
Certifications/Compliance
CE, TUV 3-1, FCC Class A
Data management details
Transfer single, range or all data points to printer or computer
Data points
2000 with Date and Time Stamp
Channels
4 (Customizable with modules)
Display type
Colour graphic LCD with user-customizable options
IP rating
IP54
Measurement modes
pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature, TDS, Conductivity, Salinity
Percent saturation range (polarographic DO)
0.0 to 600.0% saturation
Range (conductivity)
0.001 μS/cm to 3000 mS/cm
Range (mV)
±2000.0 mV
Range (pH)
-2 to 20
Range (resistivity)
2 ohm to 100.0 meg-ohm
Range (salinity)
0.06 to 80.00 psu, 0.05 to 42.00 ppt
Range (TDS)
0.001 ppm to 200.0 ppt
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (pH)
0.1/0.01/0.001
Temperature range
-5.0°C to +105.0°C
Includes
Versa Star Pro meter, VSTAR-ISE pH/ISE module, VSTAR-CND conductivity module, VSTAR-RD RDO/DO module, 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, 013005MD Orion DuraProbe 4-cell (K=0.475) conductivity sensor, 087010MD Orion RDO optical dissolved oxygen sensor, 096019 Orion Star stirrer probe …
Inputs
BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), two stirrer inputs (stirrer probe)
Isopotential point
7.000pH (adjustable), 1.000 ISE (adjustable)
Keypad
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys
Languages
English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
Log function type
Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with
Memory
Non-volatile memory preserves data log, calibration log and meter settings
Methods
10 per channel
Percent saturation relative accuracy (RDO)
±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation
Percent saturation resolution (polarographic DO)
0.1, 1% saturation
Percent saturation range (RDO)
0.0 to 500.0% saturation
Percent saturation relative accuracy (polarographic DO)
±2% saturation or ±2% of reading whichever is greater
Percent saturation resolution (RDO)
0.1, 1% saturation
Power rating
DC input: 9VDC, 1A
Power supply
Universal AC adapter (included)
Pressure range
400 to 850mmHg
Pressure resolution
0.1mmHg
Product type
Meter; pH/Ion, Conductivity and DO; Optical DO Kit
Range (ISE)
0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none
Range (ORP)
±2000.0 mV
Range (polarographic DO)
0.00 to 90.00mg/L
Range (RDO)
0.00 to 50.00mg/L
Range (relative mV)
±2000.0 mV
Relative humidity range
5 to 85%, non-condensing
Resolution (conductivity)
0.001 μS minimum, auto ranging up to 4 significant digits
Resolution (mV)
0.1mV
Resolution (polarographic DO)
0.01, 0.1mg/L
Resolution (RDO)
0.01, 0.1mg/L
Resolution (resistivity)
1 ohm or 0.1 meg-ohm, auto ranging
Resolution (salinity)
0.01 psu or 0.01 ppt minimum, auto ranging
Resolution (TDS)
0.001 ppm minimum, auto ranging up to 4 significant digits
Salinity factor
0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity
Salinity measurement modes
Practical salinity (psu) or natural sea water (ppt)
Stability
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
TDS factor range
Linear (0.02 to 9.99)
Temperature accuracy
±0.1°C
Temperature compensation
Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Temperature (english) operating
41°F to 113°F (ambient)
Temperature (metric) operating
5°C to 45°C (ambient)
Temperature (metric) reference
5°, 10°, 15°, 20°, 25°C
Temperature probe calibration
1 point temperature offset calibration
Temperature resolution
0.1°C, 0.1°F
Temperature selection
Manual or automatic with ATC temperature probe
Dimensions (L x W x H)
28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H
Weight
1.2 kg, modules add 0.2 kg each

Add this reference to my quote

Set the quantity and delivery on the interactive catalogue.

Request a quoteAll references for this item

Other references in this line