Model 43-93
Ludlum Model 43-93, alpha-beta detector
- Manufacturer
- Ludlum Measurements
- Reference
- Model 43-93
- Product line
- Detector probes: alpha, beta and gamma
Specifications
- Product
- Ludlum Model 43-93, alpha-beta detector
- Ludlum part number
- 47-2556
- Indicated Use
- Simultaneous alpha and beta survey
- Detector Type
- ZnS(Ag) scintillator adhered to 0.25 mm (0.01 in) thick plastic scintillator
- Window
- 1.2 mg/cm 2 metalized polyester
- Window Area
- Active: 100 cm 2 (15.5 in 2 ) Open: 88 cm 2 (13.6 in 2 )
- Protective Screen
- 0.79 mm (0.031 in.) thick, 6.5 mm (0.26 in.) square openings, 88% open Outer Dimensions (L x W): 168 x 92 mm (6.6 x 3.6 in.) Tool-less removal for quick window replacements
- Efficiency (4π)
- 99 Tc: 15% 90 Sr/ 90 Y: 20% 239 Pu: 20%
- Typical Background (10 µR/hr field)
- Alpha: 3 cpm or less Beta: 300 cpm or less
- Cross Talk
- Alpha to Beta: 10% or less Beta to Alpha: 1% or less
- Detector Uniformity
- Within 15% of average reading
- Gamma Sensitivity
- 15 to 20 cpm per µR/hr ( 137 Cs)
- Photomultiplier Tube
- 29 mm (1.125 in.) diameter
- Operating Voltage
- Typically 500 to 1200 V (1500 V max.)
- Temperature Range
- -20 to 40 °C (-4 to 104 °F) A version designed to be used at temperatures up to 50 °C (122 °F) is also available. See Options .
- Connector
- Series "C" (others available)
- Construction
- Aluminum with beige powder coating
- Size (H x W x L)
- 6.4 x 9.5 x 31 cm (2.5 x 3.8 x 12.3 in.)
- Weight
- 0.45 kg (1.0 lb)
- Model 3002
- Digital Survey Meter For alpha-beta counting Can store up to 1000 data points
- Model 3003 Series
- Multi-Detector Digital Survey Meter Up to 4 selectable & configurable detector settings Alpha, beta, or alpha+beta measurements Single channel analyzer Can store up to 1000 data points
- Model 2360
- Analog Datalogging Meter with Digital Scaler LCD Simultaneous alpha-beta measurements Can store up to 550 data points
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- Model 44-10Ludlum Model 44-10, gamma detector
- Model 44-11Ludlum Model 44-11, gamma detector
- Model 44-132Ludlum Model 44-132, gamma scintillator detector
- Model 44-159-1Ludlum Model 44-159-1, CsI scintillator detector
- Model 44-2Ludlum Model 44-2, gamma detector
- Model 44-20Ludlum Model 44-20, gamma detector
- Model 44-62Ludlum Model 44-62, gamma detector
- Model 43-1-1Ludlum Model 43-1-1, alpha-beta detector
- Model 43-135-1Ludlum Model 43-135-1, large area 2π proportional detector
- Model 43-143-1Ludlum Model 43-143-1, alpha-beta detector
- Model 43-147Ludlum Model 43-147, alpha-beta detector
- Model 43-2-2Ludlum Model 43-2-2, alpha-beta detector