Model 3019
Ludlum Model 3019, digital microR survey meter
- Manufacturer
- Ludlum Measurements
- Reference
- Model 3019
- Product line
- Ion chamber and micro-R dose rate meters
Specifications
- Product
- Ludlum Model 3019, digital microR survey meter
- Ludlum part number
- 48-4091
- Detector (D x L)
- Internal CsI scintillator, 2.5 x 1.9 cm (1 x 0.75 in.)
- Sensitivity
- 175 cpm per µR/hr
- Energy Range
- Nonlinear (see Energy Response Curve in the Graphs tab)
- Linearity
- Reading within 10% of true value
- Display
- 3 digit LCD with large 20 mm (0.8 in.) digits. Units: (k)cps, (k)cpm, (µ)(m)R(/h), (µ)(m)Sv(/h) Indicators: bar graph, MAX, ALARM, USB, audio, low-battery.
- Detector Range
- Background to 500 µSv/h (50 mR/hr)
- Backlight
- Built-in ambient light sensor automatically activates low-power LED backlight, unless internal dipswitch is set to continuous-On (will reduce battery life)
- User Controls
- ON/OFF: Extra-long press to turn ON; short press to acknowledge alarms; extra-long press plus 3 seconds to turn OFF UNITS: Short press changes the units between count rate, dose/exposure, or disintegration, an extra-long
- Data Logging
- Can store up to 1000 data points internally. Requires Lumic Data Logger Kit (see Options).
- Response Time
- User-selectable from 1 to 60 seconds, or Auto-Response Rate FAST or SLOW
- Alarms
- Two adjustable count rate, exposure/dose, and count alarm setpoints adjustable over the display range (see manual)
- Sigma Audio Mode
- Alarm that allows user to find small increases above the background radiation level. The instrument will beep whenever it measures a rate that exceeds a threshold rate above the measured background rate.
- Overload Protection
- High count rate saturation protection prevents false display of lower count rates. "OL" will appear on the display and an audio warning will be triggered.
- Loss of Count Protection
- After a user-settable time interval (default of 60 seconds) of no pulses from the detector, unit will flash a zero reading and the alarm audio will be triggered
- Dead Time Correction
- Employs first and second order corrections for extended performance
- Overrange
- If the reading should exceed the predefined detector range, the instrument will flash a maximum reading and trigger an audio warning.
- High Voltage
- 400 to 1500 Vdc
- Threshold
- -20 to -100 mVdc
- Audio
- Approximately 4.5 kHz, click audio greater than 65 dB at 0.6 m (2 ft), alarm audio greater than 72 dB
- Power
- Four alkaline“AA” batteries
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- Model 12SLudlum Model 12S, microR survey meter
- Model 12SALudlum Model 12SA, microR survey meter with alarm
- Model 19Ludlum Model 19, microR survey meter
- Model 192Ludlum Model 192, microR survey meter
- Model 193Ludlum Model 193, microR survey meter
- Model 19ALudlum Model 19A, microR survey meter with alarm
- Model 2401-SLudlum Model 2401-S, microR pocket-size survey meter
- Model 3192Ludlum Model 3192, background survey meter
- Model 9-3Ludlum Model 9-3, ion chamber survey meter
- Model 9-4Ludlum Model 9-4, ion chamber survey meter
- Model 9-4RFLudlum Model 9-4RF, rf-immune air ion chamber survey meter
- Model 9-7Ludlum Model 9-7, ion chamber display unit