Model 3192
Ludlum Model 3192, background survey meter
- Manufacturer
- Ludlum Measurements
- Reference
- Model 3192
- Product line
- Ion chamber and micro-R dose rate meters
Specifications
- Product
- Ludlum Model 3192, background survey meter
- Ludlum part number
- 48-4329
- Detector
- 5.1 cm diameter x 2.5 cm thick (2 x 1 in.) internal Nal(TI) scintillator
- Sensitivity
- Typically 65,000 cpm per μSv/h (650 cpm per μR/hr) ( 137 Cs gamma)
- Energy Range
- Non-linear ( see Energy Response Curve in Graphs tab )
- Linearity
- Reading within 10% of true value
- Display
- 3-digit auto-ranging LCD with large 20 mm (0.8 in.) digits. Units: (k)cps, (k)cpm, (μ)(m)R(/h), (μ)(m)Sv(/h). Indicators: bar graph, MAX, ALARM, USB, audio, low-battery.
- Detector Range
- Background to 50 μSv/h (0 to 5,000 μR/hr), 0-999 kcpm
- Backlight
- Built-in ambient light sensor automatically activates low-power LED backlight, unless internal dipswitch is set to continuous-on (will reduce battery life)
- User Controls
- ON/OFF: Extra-long press to turn ON; short press to acknowledge; extra-long press plus 3 seconds to turn OFF UNITS: Short press changes the units between count rate, dose/exposure, or disintegration, an extra-long press
- Data Logging
- Can store up to 1000 data points internally. Requires Lumic Data Logger Kit (see Options ).
- Response Time
- User-selectable from 1 to 60 seconds, or auto-response rate of FAST or SLOW
- Alarms
- Two count rate, exposure/dose, and count alarm set-points adjustable over the display range
- Sigma Audio Mode
- Alarm that allows user to find small increases above the background radiation level. The instrument will beep whenever it measures a rate that exceeds a threshold rate above the measured background rate.
- Overload Protection
- High count rate saturation protection prevents false display of lower count rates. “OL” will appear on the display and an audio warning will be triggered.
- Loss of Count Protection
- After a user-settable time interval (default 60 seconds) of no pulses from the detector, unit will flash a zero reading and the alarm audio will be triggered
- Dead Time Correction
- Employs first and second order corrections for extended performance
- Overrange
- If the reading should exceed the predefined detector range, the instrument will flash a maximum reading and trigger an audio warning.
- HV Range
- 400 to 1500 Vdc
- Threshold
- -20 to -100 mVdc
- Audio
- Approximately 4.5 kHz, click audio greater than 65 dB at 0.6 m (2 ft), alarm audio greater than 72 dB
- Power
- Four alkaline “AA” batteries
Add this reference to my quote
Set the quantity and delivery on the interactive catalogue.
Request a quoteAll references for this itemOther references in this line
- Model 12SLudlum Model 12S, microR survey meter
- Model 12SALudlum Model 12SA, microR survey meter with alarm
- Model 19Ludlum Model 19, microR survey meter
- Model 192Ludlum Model 192, microR survey meter
- Model 193Ludlum Model 193, microR survey meter
- Model 19ALudlum Model 19A, microR survey meter with alarm
- Model 2401-SLudlum Model 2401-S, microR pocket-size survey meter
- Model 3019Ludlum Model 3019, digital microR survey meter
- Model 9-3Ludlum Model 9-3, ion chamber survey meter
- Model 9-4Ludlum Model 9-4, ion chamber survey meter
- Model 9-4RFLudlum Model 9-4RF, rf-immune air ion chamber survey meter
- Model 9-7Ludlum Model 9-7, ion chamber display unit